Creating a Virtual Switch Configuration
2-4
Configuring Switches in a Stack
Creating a Virtual Switch Configuration
You
can
create
a
configuration
for
a
SecureStack
C2
switch
before
adding
the
actual
physical
device
to
a
stack.
This
preconfiguration
feature
includes
configuring
protocols
on
the
ports
of
the
“virtual
switch.”
To
create
a
virtual
switch
configuration
in
a
stack
environment:
1.
Display
the
types
of
switches
supported
in
the
stack,
using
the
show
switch
switchtype
command
7).
2.
Using
the
output
of
the
show
switch
switchtype
command,
determine
the
switch
index
(SID)
of
the
model
of
switch
being
configured.
3.
Add
the
virtual
switch
to
the
stack
using
the
set
switch
member
command
11).
Use
the
SID
of
the
switch
model,
determined
in
the
previous
step,
and
the
unit
ID
that
you
want
to
assign
to
this
switch
member.
4.
Proceed
to
configure
the
ports
of
the
virtual
switch
as
you
would
do
for
physically
present
devices.
The
following
example
adds
a
C2G124
‐
24
mode
to
a
stack
as
unit
2
of
the
stack.
The
first
port
on
that
virtual
switch
is
then
associated
with
VLAN
555.
C2(su)->show switch switchtype
Mgmt Code
SID Switch Model ID Pref Version
--- -------------------------------- ---- ---------
1 C2G124-24 1 0xa08245
2 C2K122-24 1 0xa08245
3 C2G124-48 1 0xa08245
4 C2G124-48P 1 0xa08245
5 C2H124-48 1 0xa08245
6 C2H124-48P 1 0xa08245
7 C2G134-24P 1 0xa08245
8 C2G170-24 1 0xa08245
9 C3G124-24P 1 0xa08245
10 C3G124-48P 1 0xa08245
11 C3G124-48 1 0xa08245
12 C3G124-24 1 0xa08245
C2(su)->set switch member 2 1
C2(su)->show switch
Management Preconfig Plugged-in Switch Code
Switch Status Model ID Model ID Status Version
------ ------------ ------------- ------------- --------------------- --------
1 Mgmt Switch C2G124-48 C2H124-48 OK 5.1.xx
2 Unassigned C2G124-24 Not Present 00.00.00
C2(su)->set vlan create 555
C2(su)->clear vlan egress 1 ge.2.1
C2(su)->set port vlan ge.2.1 555 untagged
C2(su)->show port vlan ge.2.1
ge.2.1 is set to 555
Note:
If you preconfigure a virtual switch and then add a physical switch of a different type to the
stack as that unit number, any configured functionality that cannot be supported on the physical
switch will cause a configuration mismatch status for that device and the ports of the new device will
join detached. You must clear the mismatch before the new device will properly join the stack.
Содержание SecureStack C2
Страница 1: ...SecureStack C2 Stackable Switches Configuration Guide Firmware Version 5 1 xx P N 9033991 16 ...
Страница 2: ......
Страница 28: ...xxvi ...
Страница 106: ...set ssl 3 52 Basic Configuration ...
Страница 226: ...Creating a Basic SNMP Trap Configuration 6 38 SNMP Configuration ...
Страница 278: ...show spantree nonforwardingreason 7 52 Spanning Tree Configuration ...
Страница 302: ...set garp timer 8 24 802 1Q VLAN Configuration ...
Страница 448: ...show dhcp pool configuration 14 30 DHCP Server Configuration ...
Страница 454: ...no license advanced 15 6 Preparing for Router Mode ...