set rmon alarm properties
SecureStack C2 Configuration Guide
13-9
set rmon alarm properties
Use
this
command
to
configure
an
RMON
alarm
entry,
or
to
create
a
new
alarm
entry
with
an
unused
alarm
index
number.
Syntax
set rmon alarm properties
index
[
interval interval
] [
object
object
] [
type
{absolute
|
delta}
]
[startup {rising
|
falling
|
either}
] [
rthresh
rthresh
]
[
fthresh
fthresh
] [
revent
revent
] [
fevent fevent
] [
owner
owner
]
Parameters
index
Specifies
an
index
number
for
this
entry.
Maximum
number
or
entries
is
50
.
Maximum
value
is
65535.
interval
interval
(Optional)
Specifies
an
interval
(in
seconds)
for
RMON
to
conduct
sample
monitoring.
object
object
(Optional)
Specifies
a
MIB
object
to
be
monitored.
Note:
This parameter is not mandatory for executing the command, but
must be specified in order to enable the alarm entry configuration.
type
absolute
|
delta
(Optional)
Specifies
the
monitoring
method
as:
sampling
the
absolute
value
of
the
object,
or
the
difference
(delta)
between
object
samples.
startup
rising
|
falling
|
either
(Optional)
Specifies
the
type
of
alarm
generated
when
this
event
is
first
enabled
as:
•
Rising
‐
Sends
alarm
when
an
RMON
event
reaches
a
maximum
threshold
condition
is
reached,
for
example,
more
than
30
collisions
per
second.
•
Falling
‐
Sends
alarm
when
RMON
event
falls
below
a
minimum
threshold
condition,
for
example
when
the
network
is
behaving
normally
again.
•
Either
‐
Sends
alarm
when
either
a
rising
or
falling
threshold
is
reached.
rthresh
rthresh
(Optional)
Specifies
a
minimum
threshold
for
causing
a
rising
alarm.
fthresh
fthresh
Specifies
a
maximum
threshold
for
causing
a
falling
alarm.
revent
revent
Specifies
the
index
number
of
the
RMON
event
to
be
triggered
when
the
rising
threshold
is
crossed.
fevent
fevent
Specifies
the
index
number
of
the
RMON
event
to
be
triggered
when
the
falling
threshold
is
crossed.
owner
owner
(Optional)
Specifies
the
name
of
the
entity
that
configured
this
alarm
entry.
Содержание SecureStack C2
Страница 1: ...SecureStack C2 Stackable Switches Configuration Guide Firmware Version 5 1 xx P N 9033991 16 ...
Страница 2: ......
Страница 28: ...xxvi ...
Страница 106: ...set ssl 3 52 Basic Configuration ...
Страница 226: ...Creating a Basic SNMP Trap Configuration 6 38 SNMP Configuration ...
Страница 278: ...show spantree nonforwardingreason 7 52 Spanning Tree Configuration ...
Страница 302: ...set garp timer 8 24 802 1Q VLAN Configuration ...
Страница 448: ...show dhcp pool configuration 14 30 DHCP Server Configuration ...
Страница 454: ...no license advanced 15 6 Preparing for Router Mode ...