set logging server
SecureStack C2 Configuration Guide
12-3
set logging server
Use
this
command
to
configure
a
Syslog
server.
Syntax
set logging server
index
[
ip-addr
ip-addr
] [
facility
facility
] [
severity
severity
]
[
descr
descr
] [
port
por
t] [
state
{
enable
|
disable
}]
Parameters
Defaults
If
ip
‐
addr
is
not
specified,
an
entry
in
the
Syslog
server
table
will
be
created
with
the
specified
index
number
and
a
message
will
display
indicating
that
no
IP
address
has
been
assigned.
If
not
specified,
facility
,
severity
and
port
will
be
set
to
defaults
configured
with
the
set
logging
default
command
If
state
is
not
specified,
the
server
will
not
be
enabled
or
disabled.
Mode
Switch
command,
read
‐
write.
Example
This
command
shows
how
to
enable
a
Syslog
server
configuration
for
index
1,
IP
address
134.141.89.113,
facility
local4,
severity
level
3
on
port
514:
C2(su)->set logging server 1 ip-addr 134.141.89.113 facility local4 severity 3
port 514 state enable
index
Specifies
the
server
table
index
number
for
this
server.
Valid
values
are
1
‐
8
.
ip
‐
addr
ip
‐
addr
(Optional)
Specifies
the
Syslog
message
server’s
IP
address.
facility
facility
(Optional)
Specifies
the
server’s
facility
name.
Valid
values
are:
local0
to
local7
.
severity
severity
(Optional)
Specifies
the
severity
level
at
which
the
server
will
log
messages.
Valid
values
and
corresponding
levels
are:
1
—
emergencies
(system
is
unusable)
2
—
alerts
(immediate
action
required)
3
—
critical
conditions
4
—
error
conditions
5
—
warning
conditions
6
—
notifications
(significant
conditions)
7
—
informational
messages
8
—
debugging
messages
descr
descr
(Optional)
Specifies
a
textual
string
description
of
this
facility/server.
port
port
(Optional)
Specifies
the
default
UDP
port
the
client
uses
to
send
to
the
server.
state
enable
|
disable
(Optional)
Enables
or
disables
this
facility/server
configuration.
Содержание SecureStack C2
Страница 1: ...SecureStack C2 Stackable Switches Configuration Guide Firmware Version 5 1 xx P N 9033991 16 ...
Страница 2: ......
Страница 28: ...xxvi ...
Страница 106: ...set ssl 3 52 Basic Configuration ...
Страница 226: ...Creating a Basic SNMP Trap Configuration 6 38 SNMP Configuration ...
Страница 278: ...show spantree nonforwardingreason 7 52 Spanning Tree Configuration ...
Страница 302: ...set garp timer 8 24 802 1Q VLAN Configuration ...
Страница 448: ...show dhcp pool configuration 14 30 DHCP Server Configuration ...
Страница 454: ...no license advanced 15 6 Preparing for Router Mode ...