Parameter overview with brief description
Parameter
Procedure
Selection/input
Factory
setting
Brightness
Enter screen brightness.
If the screensaver is enabled, the value entered here must be greater than the
minimum value for the screensaver.
20 to 100 %
100 %
User time
Enter the current, local time.
The user time is used in the measurement chart and to save the measured
values.
Entry format HH:MM:SS
The current
time is set.
User date
Enter the current date.
Entry format: DD.MM.YY
The current
date is set.
Deactivated
Tap the option to activate/deactivate the screensaver.
The display is unlocked by entering the unlock password. This function
protects the entire measuring device from unauthorized access or modification.
To only protect settings, select Settings → User settings → Unlock password →
Settings.
Enable/disable the function
The function
is disabled.
Brightness
Enter the brightness for the background lighting after the screensaver has been
activated.
The value must be less than the value specified for normal screen brightness.
20 to 100 %
100 %
Start after
Set the time that passes until the display reduces the brightness or the display lock is
activated.
Depends on the time unit
selected
• 30 to 7
200 s or
• 1 to 120 min or
• 1 to 2 h
10 s
Time unit
Set the time unit.
The value is automatically converted if the unit is changed.
• Seconds
• Minute <s>
• Hour <s>
Seconds
Lock display
Enable or disable the display lock.
Enable or disable the
function
The function
is disabled
Unlock
password
Enter the unlock password to unlock the display.
4-digit character string or
numerical sequence
LSC2
App
To prevent an unauthorized concentration app change, enter the password and
enable the function. When you tap the
Password
button the text editor opens. You
can enter the password here. Tap the
Activate/Deactivate
button to activate or
deactivate the password.
To protect the entire system from being used and modified, activate the display
lock under Settings → User settings → Screensaver → Display turn off → Lock
display.
• 4-digit character string or
numerical sequence
• Enable/disable the
function
LSC2
Settings
To prevent access to the settings (apart from the
Select concentration app
function
), enter the password and enable the function. When you tap the
Password
button the text editor opens. You can enter the password here. Tap the
Activate/
Deactivate
button to activate or deactivate the password.
To protect the entire system from being used and modified, activate the display
lock under Settings → User settings → Screensaver → Display turn off → Lock
display.
• 4-digit character string or
numerical sequence
• Enable/disable the
function
LSC2
10.4.9 Configuring the failsafe mode
The menus
Diagnosis
(transmitter with a touch screen) and
View filter
(Viewer) contain
functions to define how the device behaves when limit values are breached (under/over
range). In addition, they also contain settings for the evaluation of the measurement
results that are shown on the transmitter display.
Navigation using transmitter with touch screen
1. Settings menu → "Application parameters" → "Diagnosis" → "View options"
Содержание Teqwave F