Proline Prowirl 72
10 Technical data
E Hauser
63
10.1.8
Operating conditions: environment
Ambient temperature range
• Compact version: –40...+70 °C
(EEx d version: –40...+60°C; ATEX II 1/2 GD version/dust ignition-proof: –20...+55°C)
Display can be read between –20 °C...+70 °C
• Remote version:
Sensor –40...+85 °C
(ATEX II 1/2 GD version/dust ignition-proof: –20...+55°C)
Transmitter –40...+80 °C
(EEx-d version: –40...+60°C; ATEX II 1/2 GD version/dust ignition-proof: –20...+55°C)
Display can be read between –20 °C...+70 °C
When mounting outside, we recommend you protect from direct sunlight with a protective cover
(order number 543199), especially in warmer climates with high ambient temperatures.
Storage temperature
–40...+80 °C (ATEX II 1/2 GD version/dust ignition-proof: –20...+55°C)
Degree of protection
IP 67 (NEMA 4X) according to EN 60529
Vibration resistance
Acceleration up to 1 g, 10...500 Hz, following IEC 60068-2-6
Electromagnetic compatibility
(EMC)
To EN 61326/A1 and NAMUR Recommendation NE 21
10.1.9
Operating conditions: process
Medium temperature range
• DSC sensor (digital switched capacitor; capacitive sensor):
• Seals:
DSC standard sensor
–40...+260 °C
DSC high/low temperature sensor
–200...+400 °C
DSC sensor Inconel
(only PN 63...160, Class 600, JIS 40K and Dualsens
version)
–200...+400 °C
DSC sensor titanium Gr. 5
(PN 250, Class 900…1500 and butt-weld version)
–50...+400 °C
DSC sensor Alloy C-22
–200...+400 °C
Grafoil (graphite)
–200...+400 °C
Viton
–15...+175 °C
Kalrez
–20...+275 °C
Gylon (PTFE)
–200...+260 °C
Содержание Proline Prowirl 72
Страница 4: ...QUICK SETUP for quick commissioning Proline Prowirl 72 4 Endress Hauser...
Страница 20: ...3 Installation Proline Prowirl 72 20 Endress Hauser...
Страница 42: ...6 Commissioning Proline Prowirl 72 42 Endress Hauser...
Страница 44: ...7 Maintenance Proline Prowirl 72 44 Endress Hauser...
Страница 114: ...www endress com worldwide BA084D 06 en 12 05 71008404 FM SGML 6 0...