Proline Prowirl 72
3 Installation
E Hauser
11
3
Installation
3.1
Incoming acceptance, transport, storage
3.1.1
Incoming acceptance
On receipt of the goods, check the following points:
• Check the packaging and the contents for damage.
• Check the shipment, make sure nothing is missing and that the scope of supply matches your
order.
3.1.2
Transport
Please note the following when unpacking or transporting to the measuring point:
• The devices must be transported in the container supplied.
• Devices with nominal diameter DN 40...300 may not be lifted at the transmitter housing or at the
connection housing of the remote version when transporting (see Fig. 3). Use carrier slings when
transporting and put the slings around both process connections. Avoid chains as these could
damage the housing.
#
Warning!
Risk of injury if the measuring device slips.
The center of gravity of the entire measuring device might be higher than the points around which
the slings are slung. Therefore, when transporting, make sure that the device does not
unintentionally turn or slip.
A0001871
Fig. 3:
Instructions for transporting sensors with DN 40...300
3.1.3
Storage
Note the following points:
• Pack the measuring device in such a way as to protect it reliably against impact for storage (and
transportation). The original packaging provides optimum protection.
• The permissible storage temperature is –40...+80 °C
(ATEX II 1/2 GD version/dust ignition-proof –20...+55 °C).
• When in storage, the device should not be exposed to direct sunlight in order to avoid
impermissibly high surface temperatures.
Содержание Proline Prowirl 72
Страница 4: ...QUICK SETUP for quick commissioning Proline Prowirl 72 4 Endress Hauser...
Страница 20: ...3 Installation Proline Prowirl 72 20 Endress Hauser...
Страница 42: ...6 Commissioning Proline Prowirl 72 42 Endress Hauser...
Страница 44: ...7 Maintenance Proline Prowirl 72 44 Endress Hauser...
Страница 114: ...www endress com worldwide BA084D 06 en 12 05 71008404 FM SGML 6 0...