11 Description of device functions
Proline Prowirl 72
92
E Hauser
SIMULATION SWITCH
POINT
!
Note!
This function is not available unless the STATUS option was selected in the OPERATING
MODE function.
Use this function to activate simulation of the status output.
Options:
OFF
ON
Factory setting:
OFF
!
Note!
• The notice message #641 “SIMULATION STATUS OUTPUT” indicates that
simulation is active.
• The measuring device continues to measure while simulation is in progress, i.e. the
current measured values are output correctly via the other outputs.
"
Caution!
The setting is not saved if the power supply fails.
VALUE SIMULATION
SWITCH POINT
!
Note!
This function is not available unless the ON option was selected in the SIMULATION
SWITCH POINT function.
Use this function to define the switching behavior of the status output during the
simulation. This value is used to test downstream devices and the measuring device
itself.
User input:
NOT CONDUCTIVE
CONDUCTIVE
Factory setting:
NOT CONDUCTIVE
!
Note!
You can change the switching behavior of the status output during the simulation. The
prompt “CONDUCTIVE” or “NOT CONDUCTIVE” appears if the
O
or
S
key is
pressed. Select the desired switching behavior and start the simulation with the
F
key.
If the
F
key is pressed again afterwards, the prompt “End simulation” (NO/YES)
appears. If you choose “NO”, simulation remains active and the group selection is called
up. The simulation can be switched off again via the SIMULATION SWITCH POINT
function.
If you choose “YES”, you end the simulation and the group selection is called up.
"
Caution!
The setting is not saved if the power supply fails.
Function description PULSE/STATUS OUTPUT (status)
Содержание Proline Prowirl 72
Страница 4: ...QUICK SETUP for quick commissioning Proline Prowirl 72 4 Endress Hauser...
Страница 20: ...3 Installation Proline Prowirl 72 20 Endress Hauser...
Страница 42: ...6 Commissioning Proline Prowirl 72 42 Endress Hauser...
Страница 44: ...7 Maintenance Proline Prowirl 72 44 Endress Hauser...
Страница 114: ...www endress com worldwide BA084D 06 en 12 05 71008404 FM SGML 6 0...