3 Installation
Proline Prowirl 72
16
E Hauser
3.3
Installation
3.3.1
Mounting the sensor
"
Caution!
Please note the following prior to mounting:
• Prior to installing the measuring device in the piping, remove all traces of transport packaging and
any protective covers from the sensor.
• Make sure that the internal diameters of seals are the same as, or greater than, those of the
measuring pipe and piping. Seals projecting into the flow current have a negative effect on the
vortex formation after the bluff body and cause inaccurate measurement. For this reason, the seals
supplied by Hauser for the wafer version have a slightly larger internal diameter than the
measuring pipe.
• Ensure that the arrow on the measuring pipe matches the direction of flow in the piping.
• Lengths:
– Prowirl W (wafer version): 65 mm
– Prowirl F (flanged version)
→
See Technical Information TI070D/06/en.
Mounting Prowirl W
The centering rings supplied are used to mount and center the wafer-style devices.
A mounting kit consisting of tie rods, seals, nuts and washers can be ordered separately.
A0001888
Fig. 10:
Mounting the wafer version
1
Nut
2
Washer
3
Tie rod
4
Centering ring (is supplied with the device)
5
Seal
1
2
3
4
5
Содержание Proline Prowirl 72
Страница 4: ...QUICK SETUP for quick commissioning Proline Prowirl 72 4 Endress Hauser...
Страница 20: ...3 Installation Proline Prowirl 72 20 Endress Hauser...
Страница 42: ...6 Commissioning Proline Prowirl 72 42 Endress Hauser...
Страница 44: ...7 Maintenance Proline Prowirl 72 44 Endress Hauser...
Страница 114: ...www endress com worldwide BA084D 06 en 12 05 71008404 FM SGML 6 0...