10 Technical data
PROline Promag 10
86
Hauser
Promag H
Transmitter housing:
•
Compact housing: powder-coated die-cast aluminum
•
Remote version housing: powder-coated die-cast aluminium
Sensor housing: 1.4301
Wall mounting kit (holding plate): 1.4301
Measuring tube: stainless steel 1.4301 or 1.4306/304L
Flanges: connections generally made of 1.4404/316L
Ground rings: 1.4435/316L, Alloy C-22
Electrodes:
•
Standard: 1.4435
•
Optional: Alloy C-22
Seals:
•
DN 2...25: O-ring (EPDM, Viton, Kalrez) or moulded seal (EPDM, silicone, Viton)
•
DN 40...100: moulded seal (EPDM, silicone)
Material load diagram
The material load diagrams (pressure-temperature graphs) for the process connections
are to be found in the following documents:
•
Technical Information “Promag 10 W” (TI 093D/06/en)
•
Technical Information “Promag 10
P” (TI 094D/06/en)
•
Technical Information “Promag 10 H” (TI 095D/06/en)
Fitted electrodes
Promag W:
Measuring electrodes, reference electrodes and Empty Pipe Detection electrodes
Available as standard with: 1.4435/316L, Alloy C-22
Promag P:
Measuring electrodes, reference electrodes and Empty Pipe Detection electrodes
Available as standard with: 1.4435/316L, Alloy C-22
Promag H:
Measuring electrodes and Empty Pipe Detection electrodes
•
Available as standard with: 1.4435/316L, Alloy C-22
•
DN 2...4: without Empty Pipe Detection electrode
Process connection
Promag W:
Flange connection: DIN (dimensions to DIN 2501), ANSI, JIS
Promag P:
Flange connection: DIN (dimensions to DIN 2501), ANSI, JIS
Promag H:
•
With O-ring: flange (DIN, ANSI, JIS), external thread (ISO 228/DIN299)
•
With moulded seal: weld socket (DIN 11850, ODT), Tri-Clamp,
threaded joint (DIN 11851, DIN 11864-1, SMS1145), flange DIN 11864-2
Surface roughness
•
Measuring tube lining with PFA:
≤
0.3
µ
m (Promag H)
•
Electrodes:
1.4435/316L, Alloy C-22:
≤
0.4
µ
m
•
Promag H process connection:
≤
0.8
µ
m
(All data refer to parts in contact with medium)