3 Installation
PROline Promag 10
20
Hauser
Promag H
Flow rate characteristic values - Promag H (SI units)
Nominal
diameter
Recommended
flow rate
Factory settings
[mm]
[inch]
Min./max. full scale
value
(v ~ 0.3 or 10 m/s)
Full scale value
Current output
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut off
(v ~ 0.04 m/s)
2
1/12"
0.06 ...1.8
dm
3
/min
0.5
dm
3
/min
0.005
dm
3
0.01
dm
3
/min
4
5/32"
0.25 ...7
dm
3
/min
2
dm
3
/min
0.025
dm
3
0.05
dm
3
/min
8
5/16"
1 ...30
dm
3
/min
8
dm
3
/min
0.10
dm
3
0.1
dm
3
/min
15
1/2"
4 ...100
dm
3
/min
25
dm
3
/min
0.20
dm
3
0.5
dm
3
/min
25
1"
9 ...300
dm
3
/min
75
dm
3
/min
0.50
dm
3
1
dm
3
/min
40
1 1/2"
25 ...700
dm
3
/min
200
dm
3
/min
1.50
dm
3
3
dm
3
/min
50
2"
35 ...1100
dm
3
/min
300
dm
3
/min
2.50
dm
3
5
dm
3
/min
65
2 1/2"
60 ...2000
dm
3
/min
500
dm
3
/min
5.00
dm
3
8
dm
3
/min
80
3"
90 ...3000
dm
3
/min
750
dm
3
/min
5.00
dm
3
12
dm
3
/min
100
4"
145 ...4700
dm
3
/min
1200
dm
3
/min
10.00
dm
3
20
dm
3
/min
Flow rate characteristic values - Promag H (US units)
Nominal
diameter
Recommended
flow rate
Factory settings
[mm]
[inch]
Min./max. full scale value
(v ~ 0.3 or 10 m/s)
Full scale value
Current output
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut off
(v ~ 0.04 m/s)
1/12"
2
0.015 ...0.5
gal/min
0.1
gal/min
0.001
gal
0.002
gal/min
5/32"
4
0.07 ...2
gal/min
0.5
gal/min
0.005
gal
0.008
gal/min
5/16"
8
0.25 ...8
gal/min
2
gal/min
0.02
gal
0.025
gal/min
1/2"
15
1.0 ...27
gal/min
6
gal/min
0.05
gal
0.10
gal/min
1"
22
2.5 ...65
gal/min
18
gal/min
0.20
gal
0.25
gal/min
1 1/2"
40
7 ...190
gal/min
50
gal/min
0.50
gal
0.75
gal/min
2"
50
10 ...300
gal/min
75
gal/min
0.50
gal
1.25
gal/min
2 1/2"
65
16 ...500
gal/min
130
gal/min
1
gal
2.0
gal/min
3"
80
24 ...800
gal/min
200
gal/min
2
gal
2.5
gal/min
4"
100
40 ...1250
gal/min
300
gal/min
2
gal
4.0
gal/min