2) ORGX
(1) Definition
An X axis homing return execution application command executes a homing return function
depending on the homing direction of a parameter, and outputs the completion of
execution after completing a homing return by starting a command via a rise edge input.
Generally, the homing return execution completion output(ORIGIN FIN) is used for the
execution of other application commands.
- For reference, the “ORGRST” command is used to reset this ORIGIN FIN.
(2) Sequence and timing chart
LOAD X0.0
ORGX
OUT Y0.0
X0.0
ORGX
REQ OUT
X0.0
Y0.0
Y0.0
X축 ORIGIN FIN
X axis ORIGIN FIN