- 154 -
Chapter 9. Standard Input/ Output Signal
Chapter 9. Standard Input/ Output Signal
9.1 MC output signal(MC
Æ
PLC)
Table 9.1 MC output signal list
ADD
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
M50
MPG
ZP2
ZP1
ORG
STP
JOG
AUT
MR2
MR1
SPL
STL
AL
RST
SA
MA
M51
Pl1F
Pl1E
Pl1D
Pl1C
Pl1B
Pl1A
Pl19
Pl18
Pl17
Pl16
Pl15
Pl14
Pl13
Pl12
Pl11
Pl10
M52
Ph1F
Ph1E
Ph1D
Ph1C
Ph1B
Ph1A
Ph19
Ph18
Ph17
Ph16
Ph15
Ph14
Ph13
Ph12
Ph11
Ph10
M53
Pl2F
Pl2E
Pl2D
Pl2C
Pl2B
Pl2A
Pl29
Pl28
Pl27
Pl26
Pl25
Pl24
Pl23
Pl22
Pl21
Pl20
M54
Ph2F
Ph2E
Ph2D
Ph2C
Ph2B
Ph2A
Ph29
Ph28
Ph27
Ph26
Ph25
Ph24
Ph23
Ph22
Ph21
Ph20
M55
FlF
FlE
FlD
FlC
FlB
FlA
Fl9
Fl8
Fl7
Fl6
Fl5
Fl4
Fl3
Fl2
Fl1
Fl0
M56
FhF
FhE
FhD
FhC
FhB
FhA
Fh9
Fh8
Fh7
Fh6
Fh5
Fh4
Fh3
Fh2
Fh1
Fh0
M57
AA2
AA1
DE
DrE
P7
P6
P5
P4
P3
P2
P1
P0
M58
ALF
ALE
ALD
ALC
ALB
ALA
AL9
AL8
AL7
AL6
AL5
AL4
AL3
AL2
AL1
AL0
M59
Cl1F
Cl1E
Cl1D
Cl1C
Cl1B
Cl1A
Cl19
Cl18
Cl17
Cl16
Cl15
Cl14
Cl13
Cl12
Cl11
Cl10
M60
Ch1F
Ch1E
Ch1D
Ch1C
Ch1B
Ch1A
Ch19
Ch18
Ch17
Ch16
Ch15
Ch14
Ch13
Ch12
Ch11
Ch10
M61
Cl2F
Cl2E
Cl2D
Cl2C
Cl2B
Cl2A
Cl29
Cl28
Cl27
Cl26
Cl25
Cl24
Cl23
Cl22
Cl21
Cl20
M62
Ch2F
Ch2E
Ch2D
Ch2C
Ch2B
Ch2A
Ch29
Ch28
Ch27
Ch26
Ch25
Ch24
Ch23
Ch22
Ch21
Ch20
M63
Dl1F
Dl1E
Dl1D
Dl1C
Dl1B
Dl1A
Dl19
Dl18
Dl17
Dl16
Dl15
Dl14
Dl13
Dl12
Dl11
Dl10
M64
Dh1F
Dh1E
Dh1D
Dh1C
Dh1B
Dh1A
Dh19
Dh18
Dh17
Dh16
Dh15
Dh14
Dh13
Dh12
Dh11
Dh10
M65
Dl2F
Dl2E
Dl2D
Dl2C
Dl2B
Dl2A
Dl29
Dl28
Dl27
Dl26
Dl25
Dl24
Dl23
Dl22
Dl21
Dl20
M66
Dh2F
Dh2E
Dh2D
Dh2C
Dh2B
Dh2A
Dh29
Dh28
Dh27
Dh26
Dh25
Dh24
Dh23
Dh22
Dh21
Dh20
M67
M68
M69
1) Preparation completion signal(out) MA [
M50.0
]
Inputting power to a controller turns ON the preparation completion signal MA.
2) SERVO preparation completion signal(out) SA [
M50.1
]
If the SERVO system works normally, then the output signal SA is turned ON.
If SERVO ALARM, NOT READY, OVERLOAD, etc. take place, then it is turned OFF.
3) Controller RESET signal(out) RST[ [
M50.2
]
This is turned ON by a RST KEY or an external RESET signal(in) ERS[
M80.1
], and turned OFF by completion
of a reset.
4) Controller ALARM signal(out) AL [
M50.3
]
When an alarm happens to a controller, the content of the alarm is displayed on the screen and the
output signal AL is turned ON, and if the cause of an alarm is removed and the controller is reset, then
the alarm is cancelled and AL is turned OFF.
5) Automatic operation start(out) STL[
M50.4
], automatic operation pause(out) SPL[
M50.5
]
Automatic operation start: The command block is being executed in an auto mode.
Automatic operation pause : The execution of a command block stops in an auto mode and the
movement quantity is left.
6) Motor operation signal(out) MR1[
M50.6
], MR2[
M50.7
]
If the movement command is outputted to the motor, the signal is turned ON
7) Mode selection signal(out) AUTO[
M50.8
], JOG[
M50.9
], STP[
M50.A
], ORG[
M50.B
], MPG[
M50.F
]
The current operation mode of a controller is outputted by the relevant mode input signal.
Содержание MCU 2 Axis
Страница 1: ...User s Manual 2 AXES...