- 34 -
Chapter 2. MC Programming
25) XMOV
Input type
XMOV <P variable> or XMOV <L variable>
Terminology
<P variable>: Set the variable for a position from the Position Table.(P0 ~ P99)
<L variable>: Set the variable for a position from the L-VAR Table.(L0 ~ L1999)
Related
variable
P variable, L variable
Related command
A,D,VEL
Parameter
Maximum velocity(P18), Acceleration or deceleration time(P23), deceleration time (P65)
Explanation
Move the X-axis only by interpolation from the current position to the commanded coordinate
position at the commanded individual velocity and Acceleration or deceleration time. When it was
commanded by a P variable, the Y coordinate is ignored.
Example of use
XMOV P0
XMOV L0
XMOV PL0
XMOV LL0
26) YMOV
Input type
YMOV <P variable> or YMOV <L variable>
Terminology
<P variable>: Set the variable for a position from the Position Table.(P0 ~ P99)
<L variable>: Set the variable for a position from the L-VAR Table.(L0 ~ L1999)
Related
variable
P VARIABLE, L VARIABLE
Related command
A,D,VEL
Parameter
Maximum velocity(P18), Acceleration or deceleration time(P23), deceleration time (P65)
Explanation
Move the Y-axis only by interpolation from the current position to the commanded coordinate
position at the commanded individual velocity and Acceleration or deceleration time. When it was
commanded by a P variable, the X coordinate is ignored.
Example of use
YMOV P0
YMOV L0
YMOV PL0
YMOV LL0
Fig. 2.23 Movement function by axes
VEL 0
XMOV PO->PO setting value: 5,000, ????
VEL 1
YMOV P1-> P1 setting value: ????, 20,000
VEL 2
XMOV P2-> P2 setting value: 30,000, ????
Start point
(0.000, 0.000)
Содержание MCU 2 Axis
Страница 1: ...User s Manual 2 AXES...