- 118 -
Chapter 6. Connection
2) Example of I/O connection
1
Out +5V
2
In
PHA+(X)
3
In
PHA-(X)
4
In
PHB+(X)
5
In
PHB-(X)
6
In
PHC+(X)
7
In
PHC-(X)
8
Out
GND
9
Out ACMD(X)
10
Out
AGND(X)
11
Out 24V GND
12
In
OUTCOM0
13
Out
OUT0
(BRAKE_X)
14
Out
OUT1
(BRAKE_Y)
15
Out
OUT2
(SERVO ON_X)
16
Out
OUT3
(SERVO ON_Y)
17
In
IN0
(+Limit_X)
18
In
IN1
(-Limit_X)
19
In
IN2
(+Limit_Y)
20
In
IN3
(-Limit_Y)
21
In
IN4
(Homing_X)
22
In
IN5
(Homing_Y)
23
In
IN6
(START)
24
In
INCOM0
25
Out +24V
3) EXT-ENC: External ENCODER/MPG Connector
- Counter Connector: 5264-6/MOLEX (P: Power, I: Input, O: Output)
Pin arrangement
Pin No.
I/O
Signal name
Content
1
P/O
5V GND
External Encoder 5V Output Power
Ground
2
I
B -
External Encoder B Phase -
3
I
B +
External Encoder B Phase +
4
I
A -
External Encoder A Phase -
5
I
A +
External Encoder A Phase +
6
P/O
+5V
External Encoder 5V Output Power
Note)
a)
Pay attention to the power(+5V-GND) wiring.
b)
Be sure to wire the ‘
’ marked signal line with a Twist-Pair Shield Cable.
c)
Only a differential line driver type of external encoder or MPG can be wired.
d)
Do not insert or remove this connector after inputting power.
(Be sure to turn OFF power before insertion or removal)
24V
24V GND
IN0 ~ IN6
OUT0~
OUT3
24V
24V GND
Содержание MCU 2 Axis