- 146 -
Chapter 7. Operation
The F contact view can monitor the F00 ~ F09 area of the flag contact.
④
TC contact
The TC contact view area is a function to monitor and forcedly set a contact and variable related
to the operation of a counter and timer, so it is displayed by selecting a
tab in the
I/O explorer.
The TC contact view can monitor the contact of T0 and C0, and search and set the Timer Preset value,
Timer Value, Counter Preset value and Counter Value.
The Timer Preset value, Timer Value, Counter Preset value and Counter Value can be set in an
integer or HEX unit.
Forcedly setting of an integer unit variable
- Double clicking the integer area(DEC) of a variable to set shows an input box
on
the word area for the relevant contact.
- Entering an integer setup value in the input box
and pressing the “ENTER” key
sets a new integer value in the relevant variable.
Forcedly setting of an HEX integer unit variable
- Double clicking the HEX integer area(HEX) of a variable to set shows an input box
on the HEX integer area for the relevant contact.
- Entering a HEX integer setup value in the input box
and pressing the “ENTER” key
sets a new HEX integer value in the relevant variable.
(5) Selected I/O explorer
This is a function to sort all the contacts searchable through an I/O explorer described as above
with a selected I/O explorer and monitor its state. Up to maximum 12 contacts in different areas can
be simultaneously monitored.
Содержание MCU 2 Axis