- 13 -
Chapter 2. MC Programming
5)
DWL
Input type
DWL <number> or DWL <L variable>
Terminology
<Number>: Set a dwell time from the Dwell(E) Table.(0 ~ 9)
<L variable>: Set a dwell time from the L-VAR Table.(L0 ~ L1999)
Related
variable
D variable, L variable
Explanation
Program execution stops as much as the set dwell time(unit: msec) for the designated
variable.
Example
of
use
DWL 0
DWL L0
Operation stops for the set time of a variable ‘ DO ’ in the Dwell(E)
Table, and then continues
Operation stops for the set time of a variable ‘L0’ in the L-VAR Table
and then continues.
Example
VEL 0
MOV P0
DWL 0
VEL 1
MOV P1
Fig. 2.1 Time pause function
Pause as much as the DO variable value by a command “DWL 0”.
[Reference: External encoder pause function]
Pause by an external encoder
Parameter
P62: Encoder accumulation dwell during automatic operation
P63: Encoder Dwell [M80.5] during dwell
Explanation
Setting basic
parameter
P63 stops program execution as many as the number of set
pulses of the designated variable.
See the Fig.2.2 Pulse pause function.
Setting basic
parameter
P62 stops program execution as many as the number of set
accumulated pulses of the designated variable.
See the Fig.2.3 Accumulated pulse pause function.
(Note) The time and the pulse pause function cannot be simultaneously used.
Do not set the parameters P62 and P63 simultaneously.
Velocity
Time
F0
F1
Current position
P0 position
P1 position
Time pause
Содержание MCU 2 Axis