- 81 -
Chapter 4. PLC Program
4)
ORGRST
(1) Definition
This resets the homing return execution completion output(ORIGIN FIN) of an ORG command.
The command is started by a rising edge input.
(2) Sequence and timing chart
LOAD X0.0
ORG
OUT Y0.0
LOAD X0.1
ORGRST
OUT Y0.1
X0.0
ORG
REQ OUT
X0.0
Y0.0
Y0.0
ORIGIN FIN
ORGRST
REQ OUT
X0.1
Y0.1
X0.1
Y0.1
FIN RESET