Chapter 2. MC Programming
27) XIMOV
Input type
XIMOV <P variable> or XIMOV <L variable>
Terminology
<P variable>: Set the variable for a position from the Position Table.(P0 ~ P99)
<L variable>: Set the variable for a position from the L-VAR Table.(L0 ~ L1999)
Related
variable
P variable, L variable
Related
command
A,D,VEL
Parameter
Maximum velocity(P18), Acceleration or deceleration time(P23), deceleration time (P65)
Explanation
Move the X-axis only by interpolation from the current position to the commanded incremented at the
commanded individual velocity and Acceleration or deceleration time. When it was commanded by a P
variable, the Y coordinate is ignored.
Example
of
use
XIMOV P0
XIMOV L0
XIMOV PL0
XIMOV LL0
28) YIMOV
Input type
YMOV <P variable> or YMOV <L variable>
Terminology
<P variable>: Set the variable for a position from the Position Table.(P0 ~ P99)
<L variable>: Set the variable for a position from the L-VAR Table.(L0 ~ L1999)
Related
variable
P VARIABLE, L VARIABLE
Related
command
A,D,VEL
Parameter
Maximum velocity(P18), Acceleration or deceleration time(P23), deceleration time (P65)
Explanation
Move the Y-axis only by interpolation from the current position to the commanded incremented at the
commanded individual velocity and Acceleration or deceleration time. When it was commanded by a P
variable, the X coordinate is ignored.
Example
of
use
YIMOV P0
YIMOV L0
YIMOV PL0
YIMOV LL0
Fig.2.24 Movement function by axes
+X
XVEL 0
XIMOV P0
P0
설 정 치:5. 000 , ????
YVEL 1
Y IMOV P1
P1
설 정 치: ????, 20. 000
XVEL 2
XIMOV P2
P2
설 정 치: 30. 000 , ????
+Y
P1
P2
P0
시 점
20
.000
5. 000
(0. 000 , 0. 000)
30.000
35.000
5.000
20.000
VEL 0
XIMOV PO->PO setting value: 5,000, ????
YVEL 1
YIMOV P1-> P1 setting value: ????, 20,000
XVEL 2
XIMOV P2-> P2 setting value: 30,000, ????
Start point
(0.000, 0.000)