- 176 -
Chapter 9. Standard Input/ Output Signal
(1) Input contact area: X0.0 ~ X5.F
- Input contact area of the main unit: X0.0 ~ X1.F
Contact name Reserved contact
Contact name Reserved contact
X0.0
+Limit Switch_X
X0.7
STOP
X0.1
-Limit Switch_X
X0.8
RESET
X0.2
+Limit Switch_Y
X0.9
SERVO Ready_X
X0.3
-Limit Switch_Y
X0.A
SERVO Ready_Y
X0.4
Homing Dog Switch_X
X0.B~X0.F
General contact
X0.5
Homing Dog Switch_Y
X1.0~X1.F
Not used
X0.6
START
- Input contact area of the extended No.1 unit: X2.0 ~ X3.F
Contact name
General contact
X2.0~X3.3
Input contact area of the MCU-E module
X3.4~X3.F
Input contact area of the MCU-L module
- Input contact area of the extended No.2 unit: X4.0 ~ X5.F
Contact name
General contact
X4.0~X5.3
Input contact area of the MCU-E module
X5.4~X5.F
Input contact area of the MCU-L module
(2) Output contact area: Y0.0 ~ Y4.F
- Output contact area of the main unit: Y0.0 ~ Y0.F
Contact name
Reserved contact
Contact name
Reserved contact
Y0.0
Brake_X
Y0.5
General contact
Y0.1
Brake_Y
Y0.6
General contact
Y0.2
SERVO ON_X
Y0.7~Y0.A
General contact
Y0.3
SERVO ON_Y
Y0.B~Y0.F
Not used
Y0.4
General contact
- Output contact area of the extended No.1 unit: Y1.0 ~ Y2.F
Contact name
General contact
Y1.0~Y1.D
Output contact area of the MCU-E module
Y1.E~Y2.7
Output contact area of the MCU-L module
Y2.8~Y2.F
Not used(not defined)
- Output contact area of the extended No.2 unit: Y3.0 ~ Y4.F
Contact name
General contact
Y3.0~Y3.D
Output contact area of the MCU-E module
Y3.E~Y4.7
Output contact area of the MCU-L module
Y4.8~Y4.F
Not used(not defined)