Special Functions Menu C5x – C6x: Bit Parameters
Name Description
Addr.
(dec)
WRITE
Addr.
(hex)
WRITE
Addr.
(dec)
READ
Addr.
(hex)
READ
Def Min Max
C54 HIGH V
Rated mains voltage
541
21D 773.13 305.13 0
0
1
C55 SPEED SEARCHING Speed searching present bit 772.12
524
20C 772.12 304.12 1
0
1
C55 SPEED SEARCHING Speed searching present bit 773.2
530
212
773.2 305.2 0
0
1
C57 BRAKE UNIT
Braking module provided
515
203
772.3 304.3 0
0
1
C58FANFORCE
Forcing starting fan
534
21F
773.6 305.6 0
0
1
C60 MAIN LOSS MEM. Mains loss saving
523
20B 772.11 304.11 0
0
1
C61 ENABLE OPER.
ENABLE terminal operation
527
20F 772.15 304.15 1
0
1
C62 FIRST PAGE
First page at power on
514
202
772.2 304.2 0
0
1
C69BRK BOOST
Extrafluxing for deceleration ramp
542
21E 773.14 305.14 1
0
1
C55
bit 773.2
bit 772.12
NO 0
0
Yes 0
1
Yes A
1
1
10.3.8.
M
OTOR
T
HERMAL
P
ROTECTION
M
ENU
C6
X
Name Description
Addr.
(dec)
R/W
Addr.
(hex)
R/W
Def Min Max K
Unit
of
meas.
C65 THR.PRO.
Thermal protection enabling
1321
529
0
0
3
List
–
C66 MOT.CUR. Thermal protection pick–up current
1322
52A
105
1
120
1
%
C67 TH.C .
Motor thermal constant
1323
52B
600
5
3600
1
s
10.3.9.
S
LIP
C
OMPENSATION
M
ENU
C7
X
Name Description
Addr. (dec)
R/W
Addr. (hex)
R/W
Def Min
Max
K
Unit
of meas.
C74POLES Poles
1313 521
4
2
16
0.5 –
C75PMOT
Motor nominal power
1337
531
IF_T001=0_
T002[4]_
ELSE_T002[3]
0.5 1000
10
kW
C76 NO LOAD Motor no–load current
1325
52D
40
1
100
1
%
C77 M.SLIP
Motor rated slip
1326
52E
0
0
10
10
%
C78 Stator Res. Stator resistance
1339
533
IF_T001=0_
T002[6]_
ELSE_T002[5]
0 8.5 1000 ohm