SINUS-K
PROGRAMMING
MANUAL
143/
226
P75 Lift 17/19
P
P75
R
0÷200%
D
5%
level = *.*** %
F
Error level between the ramp block output and the motor speed determining the
output activation in mode Lift and Lift1.
P76 Lift 18/19
P
P76
R
0÷60 s
D
1 s
time = ***.* s
F
Time interval for the activation of the output in mode Lift and Lift1 if the error
between the ramp block output and the motor speed exceeds the value set in P75.
P77 Torque 19/19
P
P77
R
0÷400%
Important: the maximum programmable value is equal to (Imax/Imot)*100 (see
Table 7.4)
D
100%
lift = *** %
F
Torque value for the output activation in mode Lift.
7.2.9.
PID
R
EGULATOR
S
UBMENU
The PID Regulator submenu includes PID regulator adjusting parameters.
Access page
Press PROG (Ent) to access the first page of the PID Regulator submenu. Press
↑
(Nxt) and
↓
(Prv) to scroll through the
submenus.
First page
Press PROG (Esc) to return to the PID Regulator submenu access page. Press
↑
(Nxt) and
↓
(Prv) to scroll through the
parameters.
PROG SAVE
P.I.D. Regulator
Ent Prv Nxt
PROG SAVE
P.I.D. Reg. 1/13
Ent Prv Nxt
V
T
C