Set-up and Connection Instructions
Transport and Set-up
Transport
Each time before transporting, make
sure the lifting or transport equipment
has the lifting capacity needed to
transport the respective equipment
weight. All of the tasks described here
must be carried out based on the
relevant safety standards.
This applies not only in respect to the
equipment used, but also to the
procedures themselves. Transport
with forklifts, lifting platforms or similar
materials. Insert forks lengthwise un-
der the wooden pallet. When lifting,
make sure the weight is equally dis-
tributed. Never tilt the heat
pump beyond max. 30º (in any direc-
tion) when transporting it. Avoid ex-
posing the heat pump to any type of
moisture or humidity. (Also applies to
the set-up!)
Never stack objects on the heat pump
or hang up wet clothes over it.
Set-up
The heat pump is designed to be set
up indoors (IPXO, i.e. dry rooms on-
ly). The base frame must be set up on
a smooth, level, and plane surface.
The heat pump must be set up in a
way that allows easy access to the
pump for servicing. This is ensured by
complying with the wall clearances
depicted below.
After moving the unit to the installa-
tion location, remove the transport
protection and safety elements and
screw the “vibration-absorbent adjust-
able feet” included with delivery into
the threaded openings now exposed
at the bottom of the unit. These
adjustable feet are also used to level
the heat pump. The heat pump
should not be set up on floating
floors.
8
Plan view with minimum clearances
AQUATOP T..C..
AQUATOP T..H
Control station
Control station
m
in
4
1
0
m
m