Type
AQUATOP
Model
T22H (R) T28H (R) T35H (R)
T43H (R)
Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and out-
door temperature Tj
/ W45
Tj= -7°C
COPd
3.93
3.72
3.88
3.94
Tj= +2°C
COPd
4.8
4.54
4.76
4.84
Tj= +12°C
COPd
5.89
5.55
5.86
5.97
Tj= bivalent temperature
COPd
3.75
3.55
3.7
3.75
Tj= operation limit temperature
COPd
3.75
3.55
3.7
3.75
Cycling interval efficiency
COPcyc
3.75
3.55
3.7
3.75
Heating water operating limit temperature
WTOL
[°C]
60
60
60
60
Supplementary heater
Rated heat output
Psup
[kW]
6
6
6
6
Type of energy input
Electric
current
Electric
current
Electric
current
Electric
current
For water- or brine-to-water heat pumps: Rated
brine or water flow rate, outdoor heat exchanger
m³/h
4.14
4.84
7.17
8.67
Products information ErP
AQUATOP T22-43H(R)
74