Products information ErP
AQUATOP T22-43H(R)
Type
AQUATOP
Model
T22H (R) T28H (R) T35H (R) T43H (R)
Air-to-water heat pump
No
No
No
No
Water-to-water heat pump
Yes
Yes
Yes
Yes
Brine-to-water heat pump
Yes
Yes
Yes
Yes
Low temperature heat pump
No
No
No
No
Equipped with a supplementary heater:
Yes
Yes
Yes
Yes
Heat pump combination heater
No
No
No
No
Item
Simbolo Unità
Value
Value
Value
Value
Rated heat output
Prated
[kW]
21
27
36
43
Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj / W45
Tj= -7°C
Pdh
[kW]
21.1
27.3
36.4
43.7
Tj= +2°C
Pdh
[kW]
22.2
28.7
38.4
46.0
Tj= +12°C
Pdh
[kW]
23.6
30.4
40.6
48.8
Tj = bivalent temperature
Pdh
[kW]
20.7
26.8
35.7
42.9
Tj = operation limit temperature
Pdh
[kW]
20.7
26.8
35.7
42.9
Bivalent temperature
Tbiv
[°C]
-10
-10
-10
-10
Cycling interval capacity for heating
Pcych
[kW]
20.7
26.8
35.7
42.9
Degradation coefficient
Cdh
1.0
1.0
1.0
1.0
Power consumption in modes other than active mode
Off mode
Poff
[kW]
0.000
0.000
0.000
0.000
Thermostat-off mode
PTO
[kW]
0.010
0.010
0.010
0.010
Standby mode
PSB
[kW]
0.010
0.010
0.010
0.010
Crankcase heater mode
PCK
[kW]
0.000
0.000
0.000
0.000
Other items
Capacity control
Fix
Fix
Fix
Fix
Sound power level, indoors/ outdoors
L
WA
[dBA]
54
59
61
61
Seasonal space heating energy efficiency
η
s
%
184
174
183
186
Information products according to Directive 2009/125 / EC