12. Alarms
Rebel 80
74
-Reset lathe e-stop
-Reset lathe alarm
-Check wiring on interface
-
Check for continuity between the wires for Emergency From
Lathe (if used, check the interface drawing specific to the lathe).
-Check input on PLC (X24)
– The input should change state when the lathe alarm is turned on
and off (if used, check the interface drawing specific to the lathe).
-Parameter refers to the V-channel not lifting
-Not enough air pressure to lift channel
–
Not applicable on the Rebel 102SE
-Bind in channel opening mechanism
– Check to see if the V-channel beam is level, check
for obstructions to the V-channel.
-Pusher flag not lined up with opening
– Not applicable on the Rebel 102SE
-Pusher not at home position
– Re-zero the bar pusher.
-Flag stuck in down position
– Manually operate the measuring flag. Check for debris
impeding the operation of the flag. Check the flag for damage.
-Material impeding flag movement
– Remove the material from the flag area.
-Check flag sensor for operation
– Manually operate the flag and check to see that the LED
on the proximity switch turns on when the flag is in the closed position.
-Check input on PLC (X4)
– This input is operated by the S04 switch. The input should toggle
with the opening and closing of the measuring flag.