11. Service Technician Parameters
Rebel
80
65
Parameter Page 23
Facing Speed 1:
Forward speed of the bar pusher during the facing operation until it reaches
the Facing Speed Slowdown Distance.
Facing Speed 2:
Forward speed of the bar pusher during the distance specified in the Facing
Speed Slowdown Distance Parameter during facing. Speed pusher moves at during pecking
cycle.
Facing Speed Slowdown Distance:
Distance before pusher reaches facing position when
pusher slows down to facing speed 2. This distance is measured from the facing position back
toward the bar feeder.