12. Alarms
Rebel 80
87
-Remove material from magazine
– If material is on the magazine during the finger adjustment
the motor may stall out.
-Check for obstructions
– Check the area around the lifting fingers on the magazine for foreign
objects or debris that may block the movement of the fingers.
-Check finger/V-tray relay
– Relay R15 switches power from the V-channel motor to the finger
motor when engaged.
-Check proximity switch and input on the PLC
– The counter for the finger motor activates
prox switch S02. The input on the PLC from the switch is X0.
-V-tray position lost
– Follow the directions on the screen to reset the counter that tracks the
position of the V-channel.
-V-tray Overtravel
-The V-tray has traveled in excess of it’s limits in the up or down direction.
Follow the screen directions an use the Jog/Set V-Tray screen in the Maintenance section 8 to
recover from this alarm.