9. User Parameters
Rebel
80
48
Parameter Page 5
Open Collet Timeout:
Time between when lathe collet opens and then closes when bar feed is
in auto if time is reached then alarm is generated.
Close Collet Timeout:
Time between when lathe collet closes and then opens when bar feed
is in auto if time is reached then alarm is generated.
Open Collet Push Delay:
After lathe collet open signal is received, pusher will delay pusher
movement for set time.
Close Collet Push Delay:
After lathe collet close signal is received, pusher will continue
pusher movement for set time then stop.