Chapter 24
| CFM Commands
Defining CFM Structures
– 692 –
ethernet cfm mep
This command sets an interface as a domain boundary, defines it as a maintenance
end point (MEP), and sets direction of the MEP in regard to sending and receiving
CFM messages. Use the
no
form to delete a MEP.
Syntax
ethernet cfm mep mpid
mpid
md
domain-name
ma
ma-name
[
up
]
no ethernet cfm mep mpid
mpid
ma
ma-name
mpid –
Maintenance end point identifier. (Range: 1-8191)
domain-name –
Domain name. (Range: 1-43 alphanumeric characters)
ma-name –
Maintenance association name. (Range: 1-43 alphanumeric
characters)
up
–
Indicates that the MEP faces inward toward the switch cross-connect
matrix, and transmits CFM messages towards, and receives them from, the
direction of the internal bridge relay mechanism. If the
up
keyword is not
included in this command, then the MEP is facing away from the switch,
and transmits CFM messages towards, and receives them from, the
direction of the physical medium.
Default Setting
No MEPs are configured.
The MEP faces outward (down).
Command Mode
Interface Configuration (Ethernet, Port Channel)
Command Usage
◆
CFM elements must be configured in the following order: (1) maintenance
domain at the same level as the MEP to be configured (using the
command), (2) maintenance association within the domain (using the
command), and (3) finally the MEP using this command.
◆
An interface may belong to more than one domain. This command can be used
to configure an interface as a MEP for different MAs in different domains.
◆
To change the MEP’s MA or the direction it faces, first delete the MEP, and then
create a new one.
Example
This example sets port 1 as a DSAP for the specified maintenance association.
Console(config)#interface ethernet 1/1
Console(config-if)#ethernet cfm mep mpid 1 md voip ma rd
Console(config-if)#
Содержание AS5700-54X
Страница 42: ...Contents 42...
Страница 44: ...Figures 44...
Страница 52: ...Tables 52...
Страница 54: ...Section I Getting Started 54...
Страница 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 358: ...Chapter 9 Access Control Lists ACL Information 358...
Страница 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Страница 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Страница 442: ...Chapter 16 Address Table Commands 442...
Страница 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Страница 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Страница 544: ...Chapter 20 Quality of Service Commands 544...
Страница 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Страница 680: ...Chapter 23 LLDP Commands 680...
Страница 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Страница 732: ...Chapter 25 Domain Name Service Commands 732...
Страница 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Страница 1072: ...Section III Appendices 1072...
Страница 1090: ...Glossary 1090 XModem A protocol used to transfer files between devices Data is grouped in 128 byte blocks and error corrected...
Страница 1102: ...List of CLI Commands 1102...
Страница 1115: ......
Страница 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...