Chapter 21
| Data Center Bridging Commands
Congestion Notification Commands
– 565 –
cn cnpv defense-mode
(Global Configuration)
Use this command to configure the defense mode for a CNPV, determining
whether CN is enabled or not, and if enabled, whether the port remarks the CNPV
to a non-CNPV value on input, and whether the port removes CN-tags on output.
Use the
no
form to restore the default settings.
Syntax
cn cnpv
cnpv-priority
defense-mode
{
auto
|
disabled
|
edge
|
interior
|
interior-ready
}
no cn cnpv
cnpv-priority
defense-mode
cnpv-priority
- CN priority value. (Range: 0-7)
auto
- Defense mode and alternate priority is chosen automatically as
determined by the LLDP Congestion Notification TLV.
disabled
- CN capability is administratively disabled.
edge
- CNPV is remapped to non-CNPV and CN-TAG is removed.
interior
- Priority remapping is inhibited and CN-TAG is removed.
interior-ready
- Priority remapping is inhibited and CN-TAG is retained.
Default Setting
auto
Command Mode
Global Configuration
Command Usage
◆
Under the
auto
option, the defense mode is determined by the LLDP CN TLV,
and may be set to edge, interior, or interior-ready.
The alternate priority is also determined by the LLDP CN TLV. If CN is enabled
and the CND defense mode of the port is Edge, then the CNPV to which an
incoming frame can be mapped is the next lower priority value which is not
mapped as a CNPV, or the next higher non-CNPV, if all lower values are CNPVs.
◆
Under the
disabled
option, the congestion notification capability is
administratively disabled for this priority value and port. The priority
regeneration table controls the remapping of input frames on this port to or
from this priority. CN-TAGs are not stripped by the switch.
◆
Under the
edge
option, on this port and for this CNPV, the priority parameters
of input frames are remapped to an alternate (non-CNPV) value, and no priority
value is remapped to this CNPV regardless of the priority regeneration table.
CN-TAGs are removed from frames before being output by the switch.
◆
Under the
interior
option, on this port and for this CNPV, the priority
parameters of input frames are not remapped to another value, and no priority
value is remapped to this CNPV, regardless of the priority regeneration table.
CN-TAGs are removed from frames before being output by the switch.
Содержание AS5700-54X
Страница 42: ...Contents 42...
Страница 44: ...Figures 44...
Страница 52: ...Tables 52...
Страница 54: ...Section I Getting Started 54...
Страница 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 358: ...Chapter 9 Access Control Lists ACL Information 358...
Страница 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Страница 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Страница 442: ...Chapter 16 Address Table Commands 442...
Страница 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Страница 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Страница 544: ...Chapter 20 Quality of Service Commands 544...
Страница 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Страница 680: ...Chapter 23 LLDP Commands 680...
Страница 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Страница 732: ...Chapter 25 Domain Name Service Commands 732...
Страница 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Страница 1072: ...Section III Appendices 1072...
Страница 1090: ...Glossary 1090 XModem A protocol used to transfer files between devices Data is grouped in 128 byte blocks and error corrected...
Страница 1102: ...List of CLI Commands 1102...
Страница 1115: ......
Страница 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...