Chapter 5
| SNMP Commands
SNMP Target Host Commands
– 187 –
Related Commands
snmp-server host
This command specifies the recipient of a Simple Network Management Protocol
notification operation. Use the
no
form to remove the specified host.
Syntax
snmp-server host
host-addr
[
inform
[
retry
retries
|
timeout
seconds
]]
community-string
[
version
{
1
|
2c
|
3
{
auth
|
noauth
|
priv
} [
udp-port
port
]}
no snmp-server host
host-addr
host-addr
- IPv4 or IPv6 address of the host (targeted recipient).
(Maximum host addresses: 5 trap destination IP address entries)
inform
- Notifications are sent as inform messages. Note that this option is
only available for version 2c and 3 hosts. (Default: traps are used)
retries
- The maximum number of times to resend an inform message if
the recipient does not acknowledge receipt. (Range: 0-255; Default: 3)
seconds
- The number of seconds to wait for an acknowledgment
before resending an inform message. (Range: 0-2147483647
centiseconds; Default: 1500 centiseconds)
community-string
- Password-like community string sent with the
notification operation to SNMP V1 and V2c hosts. Although you can set this
string using the
snmp-server host
command by itself, we recommend
command prior to using the
snmp-server host
command. (Maximum length: 32 characters)
version
- Specifies whether to send notifications as SNMP Version 1, 2c or 3
traps. (Range: 1, 2c, 3; Default: 1)
auth
|
noauth
|
priv
- This group uses SNMPv3 with authentication, no
authentication, or with authentication and privacy. See “Simple
Network Management Protocol” in the
Web Management Guide
for
further information about these authentication and encryption
options.
port
- Host UDP port to use. (Range: 1-65535; Default: 162)
Default Setting
Host Address: None
Notification Type: Traps
SNMP Version: 1
UDP Port: 162
Command Mode
Global Configuration
Содержание AS5700-54X
Страница 42: ...Contents 42...
Страница 44: ...Figures 44...
Страница 52: ...Tables 52...
Страница 54: ...Section I Getting Started 54...
Страница 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 358: ...Chapter 9 Access Control Lists ACL Information 358...
Страница 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Страница 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Страница 442: ...Chapter 16 Address Table Commands 442...
Страница 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Страница 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Страница 544: ...Chapter 20 Quality of Service Commands 544...
Страница 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Страница 680: ...Chapter 23 LLDP Commands 680...
Страница 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Страница 732: ...Chapter 25 Domain Name Service Commands 732...
Страница 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Страница 1072: ...Section III Appendices 1072...
Страница 1090: ...Glossary 1090 XModem A protocol used to transfer files between devices Data is grouped in 128 byte blocks and error corrected...
Страница 1102: ...List of CLI Commands 1102...
Страница 1115: ......
Страница 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...