Chapter 22
| Multicast Filtering Commands
IGMP (Layer 3)
– 633 –
Command Mode
Interface Configuration (VLAN)
Command Usage
◆
Group addresses within the entire multicast group address range can be
specified with this command. However, if any address within the source-
specific multicast (SSM) address range (default 232/8) is specified, but no
source address is included in the command, the request to join the multicast
group will fail unless the next node up the reverse path tree has statically
mapped this group to a specific source address. Also, if an address outside of
the SSM address range is specified, and a specific source address is included in
the command, the request to join the multicast group will also fail if the next
node up the reverse path tree has enabled the PIM-SSM protocol.
◆
If a static group is configured for an any-source multicast (*,G), a source address
cannot subsequently be defined for this group without first deleting the entry.
◆
If a static group is configured for one or more source-specific multicasts (S,G),
an any-source multicast (*,G) cannot subsequently be defined for this group
without first deleting all of the associated (S,G) entries.
◆
Using the
no
form of this command to delete a static group without specifying
the source address will delete all any-source and source-specific multicast
entries for the specified group.
◆
The switch supports a maximum of 16 static group entries.
Example
The following example assigns VLAN 1 as a static member of the specified multicast
group.
Console(config)#interface vlan1
Console(config-if)#ip igmp static-group 225.1.1.1
ip igmp version
This command configures the IGMP version used on an interface. Use the
no
form
of this command to restore the default.
Syntax
ip igmp version
{
1
|
2
|
3
}
no ip igmp version
1
- IGMP Version 1
2
- IGMP Version 2
3
- IGMP Version 3
Содержание AS5700-54X
Страница 42: ...Contents 42...
Страница 44: ...Figures 44...
Страница 52: ...Tables 52...
Страница 54: ...Section I Getting Started 54...
Страница 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 358: ...Chapter 9 Access Control Lists ACL Information 358...
Страница 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Страница 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Страница 442: ...Chapter 16 Address Table Commands 442...
Страница 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Страница 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Страница 544: ...Chapter 20 Quality of Service Commands 544...
Страница 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Страница 680: ...Chapter 23 LLDP Commands 680...
Страница 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Страница 732: ...Chapter 25 Domain Name Service Commands 732...
Страница 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Страница 1072: ...Section III Appendices 1072...
Страница 1090: ...Glossary 1090 XModem A protocol used to transfer files between devices Data is grouped in 128 byte blocks and error corrected...
Страница 1102: ...List of CLI Commands 1102...
Страница 1115: ......
Страница 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...