Chapter 24
| CFM Commands
– 682 –
Specifies the name format for the maintenance association
as IEEE 802.1ag character based, or ITU-T SG13/SG15 Y.1731
defined ICC-based format
CFM
Sets an interface as a domain boundary, defines it as a
maintenance end point (MEP), and sets direction of the
MEP in regard to sending and receiving CFM messages
IC
Enables CFM processing on an interface
IC
Clears AIS defect information for the specified MEP
PE
show ethernet cfm
configuration
Displays CFM configuration settings, including global
settings, SNMP traps, and interface settings
PE
Displays configured maintenance domains
PE
Displays configured maintenance associations
PE
show ethernet cfm
maintenance-points local
Displays maintenance points configured on this device
PE
show ethernet cfm
maintenance-points local
detail mep
Displays detailed CFM information about a specified local
MEP in the continuity check database
PE
show ethernet cfm
maintenance-points
remote detail
Displays detailed CFM information about a specified
remote MEP in the continuity check database
PE
Continuity Check Operations
Sets the transmission delay between continuity check
messages
GC
Enables transmission of continuity check messages within
a specified maintenance association
GC
snmp-server enable traps
ethernet cfm cc
Enables SNMP traps for CFM continuity check events
GC
Sets the time that data from a missing MEP is kept in the
continuity check database before being purged
CFM
clear ethernet cfm
maintenance-points
remote
Clears the contents of the continuity check database
PE
Clears continuity check errors logged for the specified
maintenance domain and maintenance level
PE
Displays CFM continuity check errors logged on this device PE
Cross Check Operations
ethernet cfm mep
crosscheck start-delay
Sets the maximum delay that a device waits for remote
MEPs to come up before starting the cross-check operation
GC
snmp-server enable traps
ethernet cfm crosscheck
Enables SNMP traps for CFM continuity check events, in
relation to the cross-check operations between statically
configured MEPs and those learned via continuity check
messages
GC
Statically defines a remote MEP in a maintenance
association
CFM
Table 133: CFM Commands
(Continued)
Command
Function
Mode
Содержание AS5700-54X
Страница 42: ...Contents 42...
Страница 44: ...Figures 44...
Страница 52: ...Tables 52...
Страница 54: ...Section I Getting Started 54...
Страница 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 358: ...Chapter 9 Access Control Lists ACL Information 358...
Страница 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Страница 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Страница 442: ...Chapter 16 Address Table Commands 442...
Страница 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Страница 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Страница 544: ...Chapter 20 Quality of Service Commands 544...
Страница 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Страница 680: ...Chapter 23 LLDP Commands 680...
Страница 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Страница 732: ...Chapter 25 Domain Name Service Commands 732...
Страница 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Страница 1072: ...Section III Appendices 1072...
Страница 1090: ...Glossary 1090 XModem A protocol used to transfer files between devices Data is grouped in 128 byte blocks and error corrected...
Страница 1102: ...List of CLI Commands 1102...
Страница 1115: ......
Страница 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...