Chapter 24
| CFM Commands
Fault Generator Operations
– 717 –
more defects indicated, and fault alarms are enabled at or above the priority level
set by the
mep fault-notify lowest-priority
command.
Example
This example set the delay time before generating a fault alarm.
Console(config)#ethernet cfm domain index 1 name voip level 3
Console(config-ether-cfm)#mep fault-notify alarm-time 10
Console(config-ether-cfm)#
mep fault-notify
lowest-priority
This command sets the lowest priority defect that is allowed to generate a fault
alarm. Use the
no
form to restore the default setting.
Syntax
mep fault-notify lowest-priority
priority
no fault-notify lowest-priority
priority –
Lowest priority default allowed to generate a fault alarm.
(Range: 1-6)
Default Setting
Priority level 2
Command Mode
CFM Domain Configuration
Command Usage
◆
A fault alarm can generate an SNMP notification. It is issued when the MEP fault
notification generator state machine detects that a configured time period (see
the
command) has passed with one or more
defects indicated, and fault alarms are enabled at or above the priority level set
by this command. The state machine transmits no further fault alarms until it is
reset by the passage of a configured time period (see the
command) without a defect indication. The normal procedure upon
receiving a fault alarm is to inspect the reporting MEP’s managed objects using
an appropriate SNMP software tool, diagnose the fault, correct it, re-examine
the MEP’s managed objects to see whether the MEP fault notification generator
state machine has been reset, and repeat those steps until the fault is resolved.
◆
Only the highest priority defect currently detected is reported in the fault
alarm.
Содержание AS5700-54X
Страница 42: ...Contents 42...
Страница 44: ...Figures 44...
Страница 52: ...Tables 52...
Страница 54: ...Section I Getting Started 54...
Страница 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 358: ...Chapter 9 Access Control Lists ACL Information 358...
Страница 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Страница 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Страница 442: ...Chapter 16 Address Table Commands 442...
Страница 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Страница 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Страница 544: ...Chapter 20 Quality of Service Commands 544...
Страница 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Страница 680: ...Chapter 23 LLDP Commands 680...
Страница 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Страница 732: ...Chapter 25 Domain Name Service Commands 732...
Страница 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Страница 1072: ...Section III Appendices 1072...
Страница 1090: ...Glossary 1090 XModem A protocol used to transfer files between devices Data is grouped in 128 byte blocks and error corrected...
Страница 1102: ...List of CLI Commands 1102...
Страница 1115: ......
Страница 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...