Chapter 24
| CFM Commands
Defining CFM Structures
– 690 –
ma index name
This command creates a maintenance association (MA) within the current
maintenance domain, maps it to a customer service instance (S-VLAN), and sets the
manner in which MIPs are created for this service instance. Use the
no
form with
the
vlan
keyword to remove the S-VLAN from the specified MA. Or use the
no
form
with only the
index
keyword to remove the MA from the current domain.
Syntax
ma index
index
name
ma-name
[
vlan
vlan-list
[
mip-creation
type
]]
no ma index
index
[
vlan
vlan-list
]
index –
MA identifier. (Range: 1-2147483647)
ma-name –
MA name. (Range: 1-43 alphanumeric characters)
vlan-list
- Separate nonconsecutive VLAN identifiers with a comma and no
spaces; use a hyphen to designate a range of IDs. (Range: 1-4094).
type
– Specifies the CFM protocol’s creation method for maintenance
intermediate points (MIPs) in this MA:
default
– MIPs can be created for this MA on any bridge port through
which the MA’s VID can pass.
explicit
– MIPs can be created this MA only on bridge ports through
which the MA’s VID can pass, and only if a maintenance end point (MEP)
is created at some lower MA Level.
none
– No MIP can be created for this MA.
Default Setting
10 seconds
Command Mode
CFM Domain Configuration
Command Usage
◆
The maintenance domain used to enter CFM domain configuration mode, the
MA name and VLAN identifier specified by this command, and the DSAPs
configured with the
command create a unique service
instance for each customer.
◆
If only the MA index and name are entered for this command, the MA will be
recorded in the domain database, but will not function. No MEPs can be
created until the MA is associated with a service VLAN.
◆
Note that multiple domains at the same maintenance level (see the
command) cannot have an MA on the same VLAN. Also, each MA
name must be unique within the CFM-managed network.
◆
The first VLAN entered in the list by this command is the primary VLAN, and is
the VLAN on which all CFM functions are executed.
Содержание AS5700-54X
Страница 42: ...Contents 42...
Страница 44: ...Figures 44...
Страница 52: ...Tables 52...
Страница 54: ...Section I Getting Started 54...
Страница 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Страница 210: ...Chapter 6 Remote Monitoring Commands 210...
Страница 358: ...Chapter 9 Access Control Lists ACL Information 358...
Страница 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Страница 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Страница 442: ...Chapter 16 Address Table Commands 442...
Страница 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Страница 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Страница 544: ...Chapter 20 Quality of Service Commands 544...
Страница 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Страница 680: ...Chapter 23 LLDP Commands 680...
Страница 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Страница 732: ...Chapter 25 Domain Name Service Commands 732...
Страница 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Страница 1072: ...Section III Appendices 1072...
Страница 1090: ...Glossary 1090 XModem A protocol used to transfer files between devices Data is grouped in 128 byte blocks and error corrected...
Страница 1102: ...List of CLI Commands 1102...
Страница 1115: ......
Страница 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...