Firmware V7.16.x
16.05.2023
86/183
7.2.2 SIOX - Terminal assignment of the 230 V AC relay outputs
There are 8 relay outputs available for each extension module. For example, the outputs can be used as week
timers (e.g. for defrosting, lighting, car park lighting) or for energy management (e.g. load shedding or for
enabling of consumers). For extension modules with manual control switches (see picture), the outputs can be
switched manually. The week timers are configured in menu 4-1-4.
DANGER
Warning about dangerous electrical voltage! Danger of electric shock! BEFORE
connecting and
disconnecting, it must be checked that
no voltage is present
at the 230 V AC relay outputs! Low
voltage
and
safety extra-low voltage must
not
be applied together at all relay outputs!
•
•
In order to fuse the supply line and relay outputs, a circuit breaker with the following characteristics
must
be used for each relay output:
Rated current for 230 V AC: 6(3) A
Tripping characteristic (typical): B