Firmware V3.15
21.04.2021
302/401
•
•
•
•
•
•
Menu 2-4-3 Zone 1A Altern.
ALARM 1A POS: XXXXX
Entry
Default
High Temp Setp XX °C
High temperature setpoint at which
High
Temperature
alarm is generated
-10..30
6 °C
Low Temp Setp. XX K
Low temperature setpoint (difference below
temperature control setpoint) at which
Low
Temperature
alarm is generated
--, 0..6
4 K
Menu 2-4-4 Zone 2A Altern.
ALARM 2A POS: XXXXX
Entry
Default
High Temp Setp XX °C
High temperature setpoint at which
High
Temperature
alarm is generated
-10..30
6 °C
Low Temp Setp. XX K
Low temperature setpoint (difference below
temperature control setpoint) at which
Low
Temperature
alarm is generated
--, 0..6
4 K
Menu 2-5
Not used with this controller type
Menu 2-6 Pane Heater
PANE HTR POS: XXXXX
1 Mode Pane
Move to menu 2-6-1
2 Setpoint Pane
Move to menu 2-6-2
Menu 2-6-1 Mode Scheibe
Select between values. Checkmark shows current setting.
PANE HTR POS: XXXXX
Entry
Default
fixed run time
Pane heater fixed on time
enthalpy-ctrl rtm
Enthalpy control by ambient air temperature and
humidity
Menu 2-6-2 Setpoint Pane
SETPOINTS POS: XXXXX
Entry
Default
Mod: xxxxxxxxxxxx
Set frame heater mode (Menu 2-6-1)
Fixed on time
Mod: fixed run time xx m
Pane heater on time after actuation of Digital
Input 3 (Terminal D31 and D32)
0..120
60 m
Run Time XXX %
Fixed on time,
Only shown when mode set to Fixed On Time
(Menu 2-6-1)
--, 0..100
0 %
emerg.run time XXX %
On time in failure of ambient air humidity or
temperature signal (via CAN bus)
Only shown when mode set to Enthalpy Control
(Menu 2-6-1)
--, 0..100
0 %
Содержание UA 400
Страница 26: ...Firmware V3 15 21 04 2021 26 401 Solenoid valve Relay for Solenoid Valve 1...
Страница 133: ...Firmware V3 15 21 04 2021 133 401 Upper case and lower case can be toggled by tapping the MODE button...
Страница 172: ...Firmware V3 15 21 04 2021 172 401 Service Mode 6 7 2 SERVICE MOD...
Страница 244: ...Firmware V3 15 21 04 2021 244 401...
Страница 324: ...Firmware V3 15 21 04 2021 324 401 COOLING 1 Pos XXXXX Hystersis R4 1 xxx K Supply air temperature hysteresis setpoint...
Страница 357: ...Firmware V3 15 21 04 2021 357 401 COOLING 1 Pos XXXXX Hystersis R4 1 xxx K Supply air temperature hysteresis setpoint...
Страница 361: ...Firmware V3 15 21 04 2021 361 401 FANS 2 Pos XXXXX Fan Delay Fan delay...
Страница 372: ...Firmware V3 15 21 04 2021 372 401...
Страница 399: ...Firmware V3 15 21 04 2021 399 401 12 2 Mechanical Data DIN rail mounting A Connector set with cable All dimensions in mm...