Firmware V3.15
21.04.2021
134/401
Exit from the menus and operating screens
Press the
ESC
key to exit the menu or screen you are in at any time. This returns you to the next higher menu.
All menus and screens are closed automatically if no key is pressed for 10 minutes. The display then jumps to
the Main Menu or to the Alarm menu if any fault report is currently active (only CI 3x00 / AL 300).
8.3.2 Calling the controller menu via remote control
8.3.2.1 System Centre
The terminal for remote control of the controller (Menu 2-2 or Menu 4-2) is called in the system centre as
follows:
Step 1:
Tap "2 - System overview" or "4 - Configuration" in the main menu. If "2" is selected, the values below
are only displayed as read-only, for "4", lock-down must previously be removed by logging in (
) so that settings below can be made.
Step 2
: Tap "2 Case controllers" and select the required controller in the list that is then displayed using the
cursor buttons (↑) and (↓). In the screen that opens, the name, position designation and the alarm priority of the
controller can be input as required.
If the system centre, store computer or operator terminal remains locked down, settings on the
controller are read-only. Changes and inputs are not possible.
However, if any parametrisation is required, the lock-down for the input must be removed, see chapter
Lock-down of the setpoint change
.
Tip: Detailed descriptions for the basic configuration of the controller and its position designation or
about the settings of important parameters can be found in chapter
Содержание UA 400
Страница 26: ...Firmware V3 15 21 04 2021 26 401 Solenoid valve Relay for Solenoid Valve 1...
Страница 133: ...Firmware V3 15 21 04 2021 133 401 Upper case and lower case can be toggled by tapping the MODE button...
Страница 172: ...Firmware V3 15 21 04 2021 172 401 Service Mode 6 7 2 SERVICE MOD...
Страница 244: ...Firmware V3 15 21 04 2021 244 401...
Страница 324: ...Firmware V3 15 21 04 2021 324 401 COOLING 1 Pos XXXXX Hystersis R4 1 xxx K Supply air temperature hysteresis setpoint...
Страница 357: ...Firmware V3 15 21 04 2021 357 401 COOLING 1 Pos XXXXX Hystersis R4 1 xxx K Supply air temperature hysteresis setpoint...
Страница 361: ...Firmware V3 15 21 04 2021 361 401 FANS 2 Pos XXXXX Fan Delay Fan delay...
Страница 372: ...Firmware V3 15 21 04 2021 372 401...
Страница 399: ...Firmware V3 15 21 04 2021 399 401 12 2 Mechanical Data DIN rail mounting A Connector set with cable All dimensions in mm...