Please proceed as follows to install the device:
X
First of all set the CANopen address (node address). This
is set on the gateway via DIP switches (switches 2 - 6). The
DIP switches are located under a cover on the right-hand
side of the gateway. The valid addresses are 2 - 31.
Figure 18: Setting the slave address
X
Mount the device on the top hat rail.
Terminating resistor
Node address
OFF
ON
2 3 4 5 6 7 8
1
1
2
4
8
16
32