CV3100 series and MINI series high performance general purpose inverter instruction manual
5-10
Function
Code
Name &
Definition
Set Range
Minimun
Unit
Factory
Default
Communi
cation
Address
Modify
P5.11
AO1 gain
setting
20
~
200%
1%
100
%
050BH
○
P5.12
Reserved
050CH
P5.13
DO3 gain
setting
20
~
200%(Rating 10KHZ)
1%
100
%
050DH
○
P5.14
Reserved
050EH
P5.15
Compounding
specified
channel
setting
LED single digit:Operand 1
0
:
Keypadpotentiometer;
1
:
Digit setting
2
:
reserved
3
:
Communication setting
4
:
AI1 5
:
AI2
6: Terminal pulse.
LED tens digit
:
Operand 2
0
:
Keypadpotentiometer
1
:
Digit setting
2
:
reserved
3
:
Communication setting
4
:
AI1 5
:
AI2
6
:
Terminal pulse
LED Hundreds digit
:
Operand
3
0
:
Keypadpotentiometer
1
:
Digit setting 2
:
reserved
3
:
Communication setting
4
:
AI1 5
:
AI2
6
:
Terminal pulse
LED Thousands digit:
Reserved
1
000
050FH
×
P5.16
Compounding
specified
arithmetic
setting
LED single digit
:
Arithmetic 1
0
:
Addition 1
:
Subtraction
2
:
Absolute value
(
Subtraction
)
3
:
Choose Maximum.
4
:
Choose Minimum.
LED tens digit
:
Arithmetic 2
0
:
Addition 1
:
Subtraction
2
:
Absolute value
(
Subtraction
)
3
:
Choose Maximum.
4
:
Choose Minimum.
5
:
Operand 3 not be concerned
with operation
LED Hundreds & thousands
digit:
Reserved
1
00
0510H
○