CV3100 series and MINI series high performance general purpose inverter instruction manual
6-40
output voltage & current range is 0-10V & 0-20mA. The analog voltage or current
output is decided by jumper terminal JP2.
AO1 output=(0-10V/0-20mA)×AO1 gain setting
(
not more than 10V/20 mA
)
P5.13 defines the upper limit output of DO3. When the factory setting is 100%, the
output frequency range is 0-10KHz.
DO3 output=(0-10 KHz)×DO3 gain setting (not more than 20 KHz
)
P5.15
Compounding given channel setting
Factory setting
000
Setting range
000—666
LED single digit: Operand 1
0
:
Keypad potentiometer;
1
:
Digital setting 1
2
:
reserved
3
:
Communication setting
4
:
AI1
5
:
AI2
6
:
Terminal pulse
LED tens digit
:
Operand 2
0
:
Keyboard potentiometer
1
:
Digital setting 1
2
:
Reserved
3
:
Communication setting
4
:
AI1
5
:
AI2
6
:
Terminal pulse
LED Hundreds digit
:
Operand 3
0
:
Keyboard potentiometer
1
:
Digital setting 1
2
:
Reserved
3
:
Communication setting
4
:
AI1
5
:
AI2
6
:
Terminal pulse
LED Thousands digit: Reserved