CV3100 series and MINI series high performance general purpose inverter instruction manual
5-3
Motor and Vector control Parameter
Function
Code
Name &
Definition
Set Range
Minimun
Unit
Factory
Default
Communi
cation
Address
Modify
P1.00
Motorrated
voltage
380V
:
200
~
500V
220V
:
100
~
250V
1V
380V
220V
0100H
○
P1.01
Motor rated
current
0.1
~
600.0A
0.1A
0101H
○
P1.02
Motor rated
rev.
300
~
3000RPM
1RPM
0102H
×
P1.03
Motor rated
freq.
1.00
~
400.00Hz
0.01Hz
50.00Hz
0103H
×
P1.04
Motor
no-loading
current
0.1
~
500.0A
0.1A
0104H
○
P1.05
Motor stator
resistance
0.001
~
10.000Ω
0.001
0105H
×
P1.06
Motor rotor
resistance
0.001
~
10.000Ω
0.001
0106H
×
P1.07
Motor
inductance
0.01
~
600.00mH
0.01mH
0107H
×
P1.08
Motor mutual
inductance
0.01
~
600.00mH
0.01mH
0108H
×
P1.09
Reserved
P1.10
Rotation
deviation
compensation
0.50-2.00
0.01
1.00
010AH
○
P1.11
Pre-excitation
of-motor
selection
0
:
conditionally available
1
:
available all along
1
0
010BH
×
P1.12
Pre-excitation
continuing
time
0.1
~
10S
0.1
0.2S
010CH
×
P1.13
Motor auto
tuning
0
:
no action
1
:
statictuning
(available P0.00=0)
1
0
010DH
×
P1.14
Auto speed
regulation
(ASR)
proportion (P)
gain
0.01
~
5.00
0.01
1.00
010EH
○
P1.15
ASR
integration (I)
time constant
0.01
~
10.00S
0.01s
2.00S
010FH
○