CV3100 series and MINI series high performance general purpose inverter instruction manual
9-7
code (CRC Check).
06H: write 1 data into register
Write one value into holding register,at the time of broadcast,this function write
value into the same address register of all slave machines
Query message frame format
:
Slave a 06H + register a data c CRC CHK
| | | | |___________length
:
2byte
| | | |_______________________length
:
2byte
| | |___________________________________length
:
2byte
| |_____________________________________________length
:
1byte
|________________________________________________________length
:
1byte
Slave address
1~31
(
decimal
)
1byte
Function code
06H
1byte
Register address
Address high 8-bit
2byte
Address low 8-bit
Data content
high 8-bit
2byte
low 8-bit
CRC check code
low 8-bit
2byte
note
:
check code low 8-bit
ahead
high 8-bit
Response massage frame format:
Slave address + 06H + register a data c CRC CHK
| | | | |________length
:
2byte
| | | |___________________ length
:
2byte
| | |________________________________length
:
2byte
| |_________________________________________length
:
1byte
|____________________________________________________ length
:
1byte