Step 2: Configure the Scan Settings Pane
1.
Click the Refresh button – this resets scans in the frequency scanner made before.
2.
Type in the Start frequency in MHz you wish to use for your Frequency scan. If you type a frequency that
is too low the Start frequency will set itself to the lowest frequency this PRORXD can do.
3.
Type in the End frequency in MHz you wish to use for your Frequency scan. If you type a frequency that is
too high the End frequency will set itself to the highest frequency this PRORXD can do.
Note: The wider the band you wish to scan with the Start and Stop values, the longer the scan will be.
4.
Type in the Resolution frequency in MHz you wish to use for your Frequency scan. If you type a very
small resolution like 0.5 MHz the scan will find many more individual frequencies but the scan will be
much longer. Operating with a larger resolution will speed up the scan but can miss very small
frequency steps.
5.
Click the Apply button.
6.
The Scan Settings message window opens.
7.
Click the OK button.
Figure 7-36 Scan Settings Pane
Step 3: Start the Scan
1.
Click the Start button.
2.
The Confirm Scan message window opens. This reminds you that all usual operations will stop.
CAUTION: This means the receiver will stop channel it is receiving. Do not operate the scan if the receiver is
on air!
3.
Click the OK button.