![Dräger FTS 8000 Скачать руководство пользователя страница 79](http://html1.mh-extra.com/html/drager/fts-8000/fts-8000_operating-manual_2526524079.webp)
Troubleshooting
Edition 03 / 69 06 898
75
FTS 8000
8.4
Fault, cause and remedy
Error
Cause
Remedy
To be
completed by
Control cannot
be switched on
No power supply
Check and connect
power supply
Trainer
Main switch not switched
on
Switch on the main switch Trainer
Igniters cannot
be switched on
Safety device or
functional lock active
Check and unlock all
safety devices and
functional lock (incl.
remote control)
Trainer
Gas supply equipment
not ready for operation
Check gas supply
equipment
System owner
Shut-off valve closed
Check all shut-off valves
(open shut-off valves
slowly)
Trainer
Safety shut-off valve
closed
Reset the safety shut-off
valve
Trainer
Fault in the electrics/
electronics
Contact DrägerService
Technical
personnel
Ignition electrode faulty
Replace ignition
electrode
Specially
trained
personnel
Other ignition option
selected
Adjust the selection of the
ignition option via the
touchscreen
Trainer
Fireplaces
cannot be
activated
Gas supply equipment
not ready for operation
Check gas supply
equipment
System owner
Shut-off valve closed
Check all shut-off valves
(open shut-off valves
slowly)
Trainer
Fault in the electrics/
electronics
Contact DrägerService
Technical
personnel
Cooling time not yet
elapsed
Check cooling time,
perform any necessary
maintenance
Trainer
Support fire is not burning Turn off igniters and re-
start.
Trainer
Содержание FTS 8000