Lubricator
Air Pressure Adjustment
Adjust the operating air pressure using the black knob on top of the filter/regulator module. To increase
the pressure, turn the adjustment knob
clockwise
. The recommended pressure is 90 PSI (6,2 bar).
Warning
: Do not set the air pressure above 90 PSI (6,2 bar).
Air Filter Maintenance
The air filter removes solid particles from the air supply. The bowl located on the bottom of the filter is
equipped with an automatic float valve that will dump the solids that have accumulated in the bottom of
the filter. The float operates when the air pressure is removed from the machine.
To maintain maximum filter efficiency and air flow, clean the filter element on a quarterly basis.
Change the filter element after one (1) year of service or when the air pressure drops and cannot be
adjusted to the recommended setting after cleaning.
Caution
: Do not use a polycarbonate bowl on the filter/regulator.
A polycarbonate bowl may be damaged
and could fail if exposed to synthetic oils, thinner solvents, trichloroethylene, kerosene and other aromatic
hydrocarbons. Therefore a metal bowl is required.
14.5 Air Lubricators
The RS4203CM uses three lubricator
units: the main lubricator, the conveyor air
motor lubricator, and the voider rotary
actuator lubricator. Each of the machine’s
three lubricator units should be checked
daily and refilled as needed.
The main lubricator is mounted outside
the control box on the lower right hand
side of the machine (as shown at right).
The conveyor air motor lubricator is
located on the outside of the control box
behind the incoming air supply shut-off
and lock-out valve (refer to Chapter 11).
The voider rotary actuator lubricator is
located behind the right-side cabinet door,
below and to the right side of the voider
rotary actuator.
Use only a high quality SAE #10 pneumatic lubrication oil. Note: the use of oil with a viscosity higher than
SAE#10 will result in machine failure.
Do not overfill the lubricators. Overfilling will prevent proper viewing of fluid levels through the sight glass.
Warning
: The lubricators cannot be filled while under pressure.
D
o not attempt to remove
the plug while the air pressure is on. Always shut off and lock-out the air supply and purge