8.5 Sequence Screen
The sequence (SEQ) screen indicates the PLC status at the current step in the sequence of a clip cycle.
The sequence screen indicates the current step
of the PLC during a clip cycle. Should a fault
occur, the sequence screen displays a fault
message in place of the step indicator. Press
the fault message to access additional
information related to the cause of the fault. The
reason for the fault will be highlighted in red on
the fault message.
Also available on this screen is the ‘single step’
mode, which will allow the machine to proceed
by one step at a time each time the CYCLE
START/STOP pushbutton is pressed. To return
to normal operation, press the single step
pushbutton again, or cycle the machine with the
EMERGENCY STOP button or a guard.