49
TEMPERATURE HISTERESIS
ACCESS CODE 209
Through access code 209 the temperature histeresis, initialised at 3 ºC, can be displayed.
To change the value press ENTER, the new value (min. 1 and max. 10) and ENTER for
confirmation.
If the displayed value is correct press RESET to exit.
DISPLAYING TEMPERATURE
ACCESS CODE 210 - 211
The temperature and the changes made with the INC and DEC keys, can be displayed either in
centigrade or Fahrenheit.
Use the following code numbers:
CENTIGRADE
DEGREES
FAHRENHEIT
DEGREES
NOTE:
During programming temperature is always displayed in °C
MAXIMUM WATER LEVEL TO BE PRESELECTED IN THE TANK
ACCESS CODE 212
Through access code 212 it is possible to display and/or modify the maximum water level in the
tank to be preselected during the programming phase. The initial value is 10 cm.
The screen will display:
MAX. LEV.= CM 100
If you do not want to change it, press RESET, anyway if you want a different value, press ENTER
followed by the desired value and press ENTER again. The admissible values range from 11 cm to
100 cm
MINIMUM TANK LEVEL FOR HEATING
ACCESS CODE 213
The heating elements must be activated only if there is a minimum level in the tank. This quantity
of water varies depending on the machine and must be preselected. Through access code 213 this
value will be displayed, initialised in 10 cm.
The screen displays:
MIN. LEV. = cm 10
It is not changed by pressing RESET, anyway if you want to change the value, press ENTER
followed by the new value and then ENTER again.
The admissible values range from 2 to 30cm. Histeresis is set to 1 cm.
WORKING HOURS DISPLAY
ACCESS CODE 214
Through access code 214, the number of working hours that the programmer has been running
since the beginning of a programme until the following message is displayed, is shown for 3
seconds.
END
OF
ACTIVITIES