33
*1
Registered in FOMA terminal by &W command.
*2
Not reset by &F and Z commands.
*3
When Z command is executed before the &W command, the terminal is reset to the last status registered in memory, and
prior changes are erased.
AT+CUSD=<n>,"<str>"
*1
Set Additional service (Register USSD) of Network Services. Enter Service code provided
by DOCOMO in <str>.
n=0 : Not answer mid result (default)
n=1 : Answer mid result in "+CUSD : <m>, "<str>",0" format
m=0 : Information not requested
m=1 : Information requested
AT+CUSD? : Display current settings
AT+CUSD=? : Display a list of assignable values
AT+CUSD=0,"012345678"
OK
AT+FCLASS=<n>
*1
Set communication type supported by FOMA terminal.
n=0 : Only data supported (fixed value)
AT+FCLASS? : Display current settings
AT+FCLASS=? : Display a list of assignable values
AT+FCLASS=0
OK
AT+GCAP
Display the range of AT commands supported by FOMA terminal in the "+GCAP : <n>"
format.
n=+CGSM : Support GSM commands (including the case for supporting a part)
n=+FCLASS : SFCLASS commands
n=+W : SW commands
AT+GCAP
+GCAP : +CGSM,+FCLASS,
+W
OK
AT+GMI
Display FOMA terminal manufacturer name.
AT+GMI
FUJITSU
OK
AT+GMM
Display model name of FOMA terminal.
AT+GMM
FOMA F08A
OK
AT+GMR
Display FOMA terminal version.
AT+GMR
Ver1.00
OK
AT+IFC=<n,m>
*1
Set how to control local flow between a PC and FOMA terminal.
n, m=0 : No flow control
n, m=1 : Perform XON/XOFF flow control
n, m=2 : Perform RS/CS (RTS/CTS) flow control (default)
AT+IFC? : Display the current settings in the "+IFC:<n>,<m>" format (n and m indicate
values of DCE by DET and DTE by DCE, respectively)
AT+IFC=? : List of the settable values is displayed.
AT+IFC=2,2
OK
AT+WS46=<n>
*1
Display wireless network used when sending communication in n number.
When entering AT+WS46=<n>, ERROR is returned because it cannot be changed.
n=12 : GSM network
n=22 : 3G network (FOMA)
n=25 : GSM or 3G network (FOMA) (default)
AT+WS46? : Display current settings
AT+WS46=? : Display a list of assignable values
AT
¥
S
Display the currently set commands and S register settings.
AT
¥
S
E1 Q0 V1 X4 &C1 &D2 &S0
・・・
(snip)
・・・
S104=001
OK
AT
¥
V<n>
*1
Set whether to use expanded result codes when connection is made.
n=0 : Not use expanded result codes (default)
n=1 : Use expanded result codes
AT
¥
V0
OK
+++
Move from online data mode to online command mode when entered during a
communication.
The escape guard interval is 1 second (fixed value).
+++ (not displayed)
OK
Upper slot : Command
Lower slot : Example
Description
Содержание F-08A
Страница 256: ......
Страница 328: ......
Страница 344: ......
Страница 362: ...360 Appendix Troubleshooting Pictogram Reading Pictogram Reading...
Страница 363: ...361 Appendix Troubleshooting Pictogram Reading Pictogram Reading...
Страница 364: ...362 Appendix Troubleshooting Pictogram Reading Pictogram Reading...
Страница 365: ...363 Appendix Troubleshooting Pictogram Reading Pictogram Reading...
Страница 400: ...398 MEMO...
Страница 401: ...399 Index Quick Manual Index 400 Quick Manual 408...