Buttons of the fast pre-selection of the turbine output
Press the respective button to change the setting of the output to the said value. The data is not saved
automatically into the program memory. The buttons are active only if the mode of output control is enabled.
Button for setting the turbine output
Press the button to start the setting mode in which the buttons whose values can be changed are displayed in
red. Change the parameter value by means of the buttons +/- . The new value is saved temporarily (until the
change of the program number) by pressing the button of the parameter being set again or permanently into
the program by means of the button
.
The new value can be entered also directly via numerical keyboard after pressing the button
.
The button is active only if the output control mode is enabled.
Button for the selection of a program.
Press the button to display a pop-up menu with program options.
Press the respective button to select the desired program or cancel selecting a program by means of the button ESC
To save all changed and unsaved parameters of instrument settings to program memory, just keep the button pressed for
a longer time (approximately 2 seconds)
The save is indicated by changed color of the icon (to red) and by sound signal (2 short beeps).
After the sound beeping, all data from temporal memory are written to permanent memory.
Button to assign program for switching from foot controller
By pressing on appropriate program, the program is included
or excluded from programs switching via
foot controller side button.
If the foot controller function P# has been chosen, then by repeated pressing of this button, all the included
programs are being switched cyclically towards sequentially higher program number. After the included program achieves
highest position number, then it again gets position with lowest sequential number.
Buttons for editing the program name.
Press and hold the button for ca 2 seconds. Alphanumeric keyboard is displayed by means of which the text
can be edited. Maximum length of the text is 20 characters.
Button for setting the amount of cooling water.
Press the button to start the setting mode in which the buttons whose values can be changed are
displayed in red. Change the parameter value by means of the buttons +/- . The new value is saved
temporarily (until the change of the program number) by pressing the button of the parameter being set
again or permanently into the program by means of the button
. The new value can be entered also directly via
numerical keyboard after pressing the button
. The button is active only if the instrument cooling is turned ON.
Button to turn the instrument light on / off.
Press the button to turn ther instrument illumination on-
/ off -
.
Button to turn the instrument afterblow on / off .
Press the button to turn the instrument afterblow on
–
/ off -
. The button is active only if the cooling is
turned on.